Hydrate Formation

Hydrates do not normally form within the SJP because of high velocity of flow and the combination of HP and LP flow. If the predicted outlet temperature is within the hydrate formation band, then injection of hydrate inhibitor and / or use of heat tracing are recommended. It is usually recommended not to run the HP flow alone (for over a few minutes) without flowing the LP gas in advance.